OneVisit

Boiler On But Radiators Cold? 5 Checks Before You Call

A boiler is a different animal from a furnace. It heats water and pushes it through pipes to radiators or baseboards, so "no heat" can be a boiler problem or a water-and-air problem in the pipes. These five checks sort out which.

Safety first: if you smell gas anywhere in the house, leave and call your gas company from outside. Don't touch a switch.

1. Thermostat first, always

Mode on HEAT, setpoint a few degrees above the room. Blank or dim screen? Fresh batteries. Boilers respond slowly — give it 15–20 minutes after a change before deciding nothing's happening.

2. Is the boiler actually firing?

Stand near it. A boiler that's working makes a soft whoosh or hum when it fires, and the pipes leaving it get warm within a few minutes. If the boiler is silent and cold, treat it like a furnace that won't turn on: check the light-switch-looking power switch on or near it, and the breaker.

If the boiler fires but the radiators stay cold, the problem is downstream — keep going.

3. The pressure gauge

Most boilers have a round gauge on the front. When the system is cold it should typically read somewhere around 12–15 psi; a bit higher when hot. If it's sitting at or near zero, the system has lost water and can't circulate heat — and many boilers won't fire at low pressure on purpose.

Adding water is a simple step on some boilers and not on others (there's often a small fill valve, but overfilling causes its own problems). If you're not sure how yours works, this is a quick technician call, and it's worth knowing why it lost pressure.

4. Air in the radiators

Hot water can't get past a pocket of air. If the top of a radiator is cold while the bottom is warm, it has air in it. Each radiator has a small bleed valve at the top corner; a radiator key or flat screwdriver opens it. Hold a cup under it, open it slightly until water (not air) comes out, then close it.

Baseboard systems can have bleeders at the ends or none at all — if you don't see an obvious valve, don't go looking inside the covers.

5. Zone valves and one cold zone

If some radiators are hot and a whole area of the house is cold, that area is probably its own zone with its own thermostat and a zone valve. Check that zone's thermostat first. A zone valve that's stuck closed is a common part failure; that's a technician fix.

When it's a pro

Boiler silent with power and gas confirmed, pressure at zero that keeps returning to zero after filling, a circulator pump that hums but doesn't move water, or a zone that stays cold after its thermostat checks out — call.

Before you do, run the free troubleshooter. It has a boiler path that captures what's hot, what's cold, and the gauge reading, and gives you a summary to read to the dispatcher.

Related symptoms

Start the free troubleshooter → Free. No sign-up. Don't pay $150 to flip a switch.

Start the free troubleshooter →

Free · no sign-up · no personal info · about ten minutes